Conventional Fire Extinguishing Control Panel
Conventional series fire extinguishing control panel operates on cross-zone principle, has 4 detection zones and one extinguishing release output which is programmable according to the zone requirements. Conventional extinguishing control panel is microprocessor controlled, offers high performance and can easily be integrated into all extinguishing projects.
Compatible with EN 12094-1, EN 54-2 and EN 54-4 standards
4 detection zones, 1 extinguishing zone
Extinguishing-related front panel LEDs and LCD screen provide full system information
Display of two warnings from two devices on the detection zones with fire zone LED

 

Central de detecção alarme e combate a incêndio, combate a incêndio, fm-200, fm200, co2, novec, inergen, agentes limpos.

Gas Alarm Control Panel(لوحة تحكم لانذار الغاز), 4 Channel Gas Alarm Control Panel((لوحة تحكم لانذار الغاز لأربع خطوط, 4 zone Gas Alarm Control Panel(لوحة تحكم لانذار الغاز لأربع مناطق), Gas Detection Control Panel(لوحة تحكم كشف الغاز), Conventional Gas Detection System(نظام كشف الغاز التقليدي), Dust Proof Smoke Detector(كاشف دخان مميز للغبار),

Portfolio Item
Product Manual
Portfolio Item
Wiring Diagram
Portfolio Item
Sales Support Documents
Portfolio Item
Technical Support Document

Event log can be monitored via PC software

Sending event log via RS-232 to PC or printer

There are two extinguishing operating types; automatic and manual or manual only

Detection zones can be tested or disabled, 1. and 2. Level relay output, extinguishing output and extinguishing abort button can be disabled

Inputs and outputs of panel, inputs and outputs of expansion module can be programmed via special PC software. Possibility of assigning gas active, remote alarm, remote reset and many more features to the inputs

Supervized extiguishing output, second level sounders, gas release output

Extinguishing mode can be changed remotely with extinguishing status key input

Fire and fault relays

Dry contact relay output for fire and fault

Dry or energized contact options for outputs

Favorable structure for integration with mechanical systems

Cross-zone operation can be selected to be active/passive via PC software

Up to 1000 events log memory

Adjustable first level delay time to sounders

Adjustable delay time to detection zones

Configurable delay and extinguishing time

Non-latching zone option

Countdown clock until the starting of extinguishing

Fire and fault LEDs for each detection zone

Supervised zone detection inputs, extinguishing hold input, extinguishing abort input, extinguishing activation input, low pressure input.

Real time clock